Downloads
- Multi-Parameter input selection
- Optional field upgradeable relays
- Dial-type digital bar graph
The 9900 Multi-Parameter Transmitter has superseded most of Signets previous range of individual Transmitters and Indicators, please contact us if you have further questions about its suitability for your needs.
The Signet 9900 Multi-Parameter Transmitter provides a single channel interface for various parameters. These include flow, pH/ORP, Conductivity/Resistivity, Salinity, Pressure, Temperature, Level and other sensors that output a 4 to 20 mA signal. The 9900 transmitter (generation II) has the added capability of supporting the batch module for batching control.
The extra large (3.90 x 3.90) auto-sensing back-lit display features at-a-glance visibility that can be viewed at 4-5 times the distance over traditional transmitters. The highly illuminated display and large characters reduce the risk of misreading or misinterpreting the displayed values. The display shows separate lines for units, main and secondary measurements as well as a ‘dial-type’ digital bar graph.
The 9900 is offered in both panel or field mount versions. Both configurations can run on 12 to 32 VDC power (24 VDC nominal). The 9900 can also be loop powered with compatible sensors.
Designed for complete flexibility, plug-in modules allow the unit to easily adapt to meet changing customer needs. Optional modules include Relay, Direct Conductivity/Resistivity, H COMM, Batch and a PC COMM configuration tool. The unit can be used with default values for quick and easy programming or can be customised with labelling, adjustable minimum and maximum dial settings, and unit and decimal measurement choices.
Features of the Signet 9900 Multi Parameter Transmitter include:
- Multi-Parameter input selection
- Large auto-sensing backlit display with at a glance visibility
- Dial-type digital bar graph
- Intuitive and user-friendly interface consistent with legacy Signet ProPoint® and ProcessPro® devices
- Optional field upgradable relays
- Selectable error mode for current outputs, 3.6 mA or 22 mA
- 4 to 20 mA input (with optional 8058 Signal Converter)
- Warning LED indicator
- Custom 13-character label capabilities for the channel type
- Factory reset capability
- Optional PC COMM configuration tool
- Optional H COMM module for two-way communication
- Optional Batch Module for Batch Control
Typical Applications:
- Wastewater Treatment
- Reverse Osmosis
- Deionization
- Ultra Pure Water
- Two Bed System
- Mixed Bed System
- Chemical Manufacturing/Addition
- Metal and Plastic Finishing
- Fume Scrubber
- Cooling Towers
- Media Filtration
Specs
Contact Us Today To Enquire About Our Products And Services
Specification Detail of the 9900 Multi Parameter:
Input Channels
One
Input Types
Digital (S3L): Serial ASCII, TTL Level, 9600 bps;
Frequency: Range – 0.5 to 1500Hz, Accuracy – 0.5% of reading
Measurement Types
Flow, pH/ORP, Conductivity/Resistivity, Salinity, Pressure, Temperature, Level, Dissolved Oxygen, Batch or user-defined
Materials
Case: PBT
Window: shatter resistant glass
Keypad: 4 buttons, injection moulded silicon rubber seal
Display: Back-lit and 14-segment
Operating Temp Range
-15° to 70°C
Display Ranges
Flow Rate: -9999 to 99999 units per second, minute, hour or day;
Pressure: -40 to 1000psi, Totaliser: 0.00 to 99999999 units
Output
Current output – One (1); Two (2) with 4 to 20 mA output module
Relay Specifications
Dry-Contact Relays (2), Open Collector (1)
Fluid Type
Liquids
Applicable Liquids
Clean water, dirty water
Input Power
DC: 10.8 to 35.2 VDC, regulated, 9900 without relay module: 200mA @ 10.8 to 35.2 VDC, 9900 with relay module: 300mA @ 10.8 to 35.2 VDC
Approvals
CE
Enclosure Rating
NEMA 4X/IP65 (front face only on panel mount); field mount is 100% NEMA 4X/IP65