Water Meters & Heat Meters – Parameter Comparison

Parameter Comparison Table

Acceptable fluid Flow range (m3/hr) Nominal size (mm) Linearity Operating temperature (°C) Max operating pressure (Bar) ATEX approval
Multi Jet Water Meter Water 1.5 – 15 (nominal) 15, 20, 25, 32, 40, 50 cold (30°C) or hot (90°C) 16 No
Woltmann Water Meter Water 15 – 1500 (nominal) 50, 65, 80, 100, 125, 150, 200 cold (30°C), hot (90°C) or high temp (130°C) 16 No
Heat Energy Meter Package: Multi Jet Water Meter + Heat Energy Calculator Water 1.5 – 15 (nominal) 15, 20, 25, 32, 40, 50 cold (30°C) or hot (90°C) 16 No
Heat Energy Meter Package: Woltmann Water Meter + Heat Energy Calculator Water 15 – 1500 (nominal) 50, 65, 80, 100, 125, 150, 200 cold (30°C), hot (90°C) 16 No
ICT Heat Energy Calculator Liquid N/A N/A 5 – 150 No
ICT Heat Meter for HVAC & Building Services Liquid 0.6, 1.5 or 2.5 20, 25 25 – 90 No
ICT Ultrasonic Heat Meter Liquid 0.6 to 60 15 – 100 1 – 130 16 (threaded) or 20 (flanged) No
Pro V M22 EM Vortex Heat Meter  Liquid  0.2 – 970 m³/hr  -200 to 400°C  175bar  Yes

The data above is intended as a guide for selection. Please check datasheets before specifying

Need advice?

iCenta is a UK flow meter specialist with experience in Flow technologies for diverse applications, fluid types and process conditions. Call iCenta now for advice, sales & technical information on 0844 543 0844 or email [email protected]

Contact Us

Back to Technical Product Comparison