Variable Area Flow Meters & Rotameters

Parameter Comparison Table

Acceptable fluid Flow rate range (m³/hr) Output Accuracy (%) Sensor body Operating temperature (°C) Max operating pressure (bar)
Rotameter Flow Meter F VA Trogflux Liquid, gas Liquid: 0.0125 – 25Gas: 2 – 430 No 2.5 or better Plastic 60 (50 water) 10
Rotameter Flow Meter F VA Tubux Liquid, gas Liquid: 0.001 – 25Gas: 0.016 – 400 No 1.6 or better Metal or plastic 150 up to 10
Rotameter Flow Meter F VA Tubux M30 Liquid, gas Liquid: 0.001 – 10Gas: 0.032 – 180 No 1.6 or better Metal or plastic 150 up to 10
Rotameter Flow Meter F VA Unox Liquid, gas Liquid: 0.001 – 25Gas: 0.016 – 400 No 1.6 or better Steel/stainless steel 150 up to 10
Rotameter Flow Meter F VA 250 Liquid, gas Liquid: 0.016 – 100Gas: 0.5 – 630 0 – 20 mA 1.6 or better Stainless steel 300 40
Rotameter Flow Meter F VA Minix Liquid, gas Liquid: 0.0001 – 0.500Gas: 0.002 – 8.0 No 2.5 or better Aluminium & brass/stainless steel 70 10
Low Flow Rotameter Q flow for Liquids & Gases Liquid, gas Liquid: 0.00025 – 0.07Gas: 0.00012 – 1.2 No 2, 4 or 5 Aluminium or stainless steel 100 max 16 or 20
Low Flow Rotameter V 100 for Liquids & Gases Liquid, gas Liquid: 0.00025 – 0.07Gas: 0.00012 – 1.2 No 2, 4 or 5 Aluminium or stainless steel 100 max 16 or 20
Micro Needle Valve M flow none none none none none none none
Variable Area Flow Meters from GF none none none none none none none

The data above is intended as a guide for selection. Please check datasheets before specifying

Need advice?

iCenta is a UK flow meter specialist with experience in Flow technologies for diverse applications, fluid types and process conditions. Call iCenta now for advice, sales & technical information on 0844 543 0844 or email [email protected]

Contact Us

Back to Technical Product Comparison