Parameter Comparison Table

Acceptable fluidFlow range (m3/hr)Nominal size (mm)LinearityOperating temperature (°C)Max operating pressure (Bar)ATEX approval
Metri IC-LTM Turbine Flow MeterLiquid0.28 – 5506 – 150 (12 models)< ± 0.25% of reading350 max400 (with threaded connection)Yes
Metri IC-GTM Turbine Flow MeterGas0.3 – 1960(19 model/size versions)±2.0%-30 to +120Llimited only by end fittings*
2100 Turbine Flow SensorLiquid0.02 – 2.38, 10, 15(3 models)± 3%-20 to 7016 (@20 °C)No
EX Turbine FlowmeterLiquid0.6 –450015 – 400(13 models)± 0.35% or ± 0.15%30 – +12030 – +300 (high temp model)-200 – –30 (low temp model)51Yes

The data above is intended as a guide for selection. Please check datasheets before specifying

Need advice?