Acceptable fluid Flow range (m3/hr) Nominal size (mm) Linearity Operating temperature (°C) Max operating pressure (Bar) ATEX approval
IC LTM Turbine Flow Meters Liquid 0.28 – 550 6 – 150 (12 models) < ± 0.25% of reading 350 max 400 (with threaded connection) Yes
Turbine Flow Meter IC GTM Gas 0.3 – 1960 (19 model/size versions) ±2.0% -30 to +120 Llimited only by end fittings *
Turbine Flow Sensor Signet 2100 PVDF Liquid 0.02 – 2.3 8, 10, 15(3 models) ± 3% -20 to 70 16 (@20 °C) No
Flow Meter OVAL EX Turbine Liquid 0.6 –4500 15 – 400(13 models) ± 0.35% or ± 0.15% 30 – +12030 – +300 (high temp model)-200 – –30 (low temp model) 51 Yes